All users please be aware that the forum will switch to the new format this weekend (May 2-3 2026). You will see some changes in font and color and location of posts but basic functions should remain the same. Please post to the Help category if you experience issues.
Thanks
qhumberd
Moderator
Thanks
qhumberd
Moderator
-
Re: City Water Problem
The internal pressure regulator that NuCamp was installing in the 2022 versions for a short period of time, turned out to be an 80 psi regulator. I removed mine and replaced it with a piece of PEX as… -
Re: WFCO WF-8735-AD + LiFePO4: FYI on annoying 'auto detect' quirk
The WFCO 8735 has a 30A fuse for the charger circuit going to the battery. This means that there must be separate converter and charging circuitry in the unit. When on shore power the converter will … -
Re: 2022 T@B320 Lithium upgrade
I have a 2022 and just upgraded to Lithium - Battleborn 100aH. I have a 320S BD with the WFCO power converter - 8735LiS. Be aware that the wiring from the converter to the battery in the Tub is 10AWG… -
Re: Lithium Charging voltage low in Bulk mode
Looks like you have a 400. Mine is a 320 and only 35A WFCO (8735Li) - after internal DC loads I don't get that much charge current when on shore power. My motivation was to avoid moving battery … -
Re: Lithium Charging voltage low in Bulk mode
Bad battery was an issue, but everything I read said you needed to charge lithium batteries at 14.2 - 14.4 volts (constant voltage) to balance the cells. You just can't do that with the WFCO and…