Re: Corrosion of Alde Convectors
Also, after cleaning the outside of our convector pipe stubs, I remembered I had some silicone conformal coating liquid, so I just painted the remaining three convectors with that before I add the he… -
Re: Corrosion of Alde Convectors
Well, let us know how the Evan's fluid works out for you, @Dalehelman. By the way, I'm only 4 yrs behind you, so I feel those tight spaces too. That's why, today, rather than trying to… -
Re: Corrosion of Alde Convectors
Here are photos of our rear driver-side convector connectors.. Only the top one (first one from Alde) has been cleaned up. Lower one has some raised white deposits on it. And both cleaned.. Next is t… -
Re: Corrosion of Alde Convectors
CAUTION!..03/26/2023: The heat shrink tubing referenced below has glue inside that failed on a hot convector & slipped off, releasing glycol from our system. While I continue to use it, I have ad… -
Re: Corrosion of Alde Convectors
Haven't yet drained our glycol, but getting closer. I wanted to first get the convectors exposed for inspection for corrosion later, so tackled the removal of the rear storage bin. Removing the …