Re: battery not holding charge
@Tenacity - you should have a charge wire installed on your TV that connects to the TV 7 pin harness. That provides the ability to charge the TaB battery when the battery switch is turned on, so you … -
Re: 2022 Tab 320 BD, use Alde heater with plumbing drained?
@dsfdogs and @kottum - just a correction, the Alde water tank hot water line exits the top of the tank, so the hot water low point drain does not drain the Alde water tank, it only drains the hot wat… -
Re: TAB 320S BD City Water overflowing
@ageo - The single clear hose under the TaB is for the Alde Safety/Drain (yellow flapper valve). The clear hose that exits the top of the Alde is to allow air to enter the Alde water tank to assist t… -
Re: Very poor hot water flow
@Edward - there have been several reports of defective mixing valves. It sounds like that is the problem. Contact a dealer to get the parts under warranty. -
Re: 2022 T@b CS-S lithium battery
Your 2022 CSS should have the lithium compatible converter. You may have a converter with a switch or the WFCO 8735-AD model which automatically detects the battery type. If you install lithium, you …