Alde main circulation pump circuit board on back of motor burnt up M/N D5vario 38/000 S/N50371977. There is 12v power going to this motor all the time when battery switch is on. The Alde 3020 controller is not controlling power to this pump. That's why it burnt up. There is power to the pump when the wire from the 3020 is disconnected at the board at the boiler. My thought is; there is a relay on the board that is bad stuck closed to power the pump. Anybody had this problem? Or other ideas. Sincerely Tim Tab 400 BB 2022 Alde M/N 30209300 S/N 371145
Installed new board pump works fine no voltage when pump is off cont operation and works fine when on. Might look into repairing old board as spare. There are two relays K1 and K2 one of which might … (View Post)
Amendment to my first post. Removed the pump and bench tested with 12v battery; pump does run. The control board will not run the pump even though I get a 12v reading with my meter. I think the volta… (View Post)