For the Power Pad not being centered can make the Green LED invisible from many viewing angles and dim when visible.

MuttonChops said:Are you 100% sure the indicator light (LED) is not on.
One trailer builder web-page has this comment:
Turn ON the Alde system by pressing the power button on the left. The power button has a little green light just right of center but you may need to look at it straight on to see it.

OK, let's recap.
We have a Sink and Outside Shower plumbing
configuration.
The Adle is correctly in By-Pass mode.
When City Water is connected, everything works
correctly . . . hot & cold water have pressure and flow.
When City Water is not connected and the Pump
is used, pressure/flow stop as soon as city water built up pressure
is released/used.
So something is wrong with the Pump or Pump
water lines.

[] fresh water tank vent could be blocked - - -
low likelihood
[] fresh water feed line could be blocked - - -
can you blow air into the hose (hose that connects to Pump filter) and
hear bubbles in the tank?
[] Are all pump fitting air tight? No leaks.
[] If sure pump feed line is clear and no air leaks, time to
remove the pump.
Consider Taking Pump apart**, confirm there is no
junk in the passages, put back together and try pumping again.